摘 要:目的采用大规模平行测序检测胎儿染色体疾病,通过全面随访,为无创产前检测(NIPT)的临床应用提供有效的数据支持及遗传咨询方案。方法唐氏筛查高风险的孕妇接受NIPT,结果提示高危者进行核型确诊,低危者进行生育前后随访。结果 (1)NIPT提示胎儿异常25例,异常率为1.49%,核型确诊异常12例,均已引产,NIPT对T21、T18、XO、XXY、XYY的准确性依次为99.93%、100.00%、99.66%、100.00%、100.00%;在高龄妊娠和双胎妊娠中对T21/T18的准确性达100.00%;产前阳性干预率达100.00%。(2)NIPT提示低风险1 651例,完成随访1 468例,成功率为88.91%,发现1例9号染色体倒位(母源性)。(3)B超检测染色体异常准确率达98.17%,检出率仅7.69%;唐氏筛查高风险人群的准确率仅为0.88%,假阳性率高达99.12%;NIPT避免了98.71%的孕妇进行介入性产前诊断。结论 NIPT作为现有产前检测技术的重要补充,为寻找最合适的产前筛查模式提供参考。在医疗机构建立健全NIPT随访和服务系统对降低出生缺陷疾病尤为重要。Objective To provide valid data and useful genetic counseling in the clinical application of non-invasive prenatal test(NIPT),fetal chromosomal disorder were screened by massive parallel sequencing and made a follow-up study.Methods Pregnant women with Down screening in high-risk were screened by NIPT;NIPT verified high-risk individuals were suggested for karyotyping;and we follow up on whoever showed low risk by NIPT before and after their deliveries.Results(1)Totally 1 676 cases of pregnant women were tested by NIPT,25 cases prompted to be abnormal,with an abnormal rate of 1.49%,karyotype analysis results in 12 cases of abnormalit,the accuracies of NIPT for T21,T18,XO,XXY,and XYY were 99.93%,100.00%,99.66%,100.00%,100.00%respectively;the accuracy of NIPT for women with advanced paternal age and twins were both 100.00%;karyotyping positive individuals underwent abortion,which gives a prenatal intervention rate of 100.00%.(2)Out of 1 651 cases of NIPT low risk testers,1 468 cases were successfully followed up,with a 88.91% success rate.We found chromosome abnormality with one case of inversion of chromosome 9(maternal).(3)Ultrasound-detection possessed 98.17% accuracy and 7.69%in detection rate;in high-risk pregnant woman,Down screening had an accuracy of 0.88% and false positive rate of 99.12%;98.71%women were avoided prenatal diagnosis via NIPT.Conclusion Compare to ultrasound and maternal plasma screening,NIPT is a far more accurate prenatal screening approach.To build effective follow-up and service systems of NIPT is necessary to reduce birth defects in medical institutions.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.216.196.208