检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:钱程[1] 谷波[1] 田镇[1] 马磊[1] 杨林[2]
机构地区:[1]上海交通大学制冷与低温工程研究所,上海200240 [2]上海交通大学汽车电子技术研究所,上海200240
出 处:《上海交通大学学报》2016年第4期569-574,共6页Journal of Shanghai Jiaotong University
基 金:国家科技支撑项目(2013BAG03B01)资助
摘 要:针对纯电动汽车双热源热泵系统,采用单一空气源热泵模式和双热源热泵模式进行系统实验,得到系统的性能参数,推得各部件损失占比等.结果表明:吸取1kW废热后,制热量和能效比最大,分别提高了46.58%和28.07%;部件相对损失占比最大的为压缩机46.64%~50.07%,其次是冷凝器30.09%~33.40%.For the dual source heat pump in electric vehicles,experiments were conducted in air source heat pump(ASHP)and dual source heat pump(DSHP)mode.The heating performance characteristics were obtained and exergy loss ratio was deduced.It turns out that the heating capacity is 46.58% higher than that without waste heat and the coefficient of performance(COP)is 28.07% higher at most.The compressor accounts for most exergy losses of up to 46.64% to 50.07% while the condenser reaches 30.09% to33.40%.