Effects of posterior corneal astigmatism on the accuracy of AcrySof toric intraocular lens astigmatism correction  被引量:4

Effects of posterior corneal astigmatism on the accuracy of AcrySof toric intraocular lens astigmatism correction

在线阅读下载全文

作  者:Bin Zhang Jing-Xue Ma Dan-Yan Liu Cong-Rong Guo Ying-Hua Du Xiu-Jin Guo Yue-Xian Cui 

机构地区:[1]Department of Ophthalmology,the Second Hospital of Hebei Medical University

出  处:《International Journal of Ophthalmology(English edition)》2016年第9期1276-1282,共7页国际眼科杂志(英文版)

摘  要:AIM:To evaluate the effects of posterior corneal surface measurements on the accuracy of total estimated corneal astigmatism.METHODS:Fifty-seven patients with toric intraocular lens(IOL) implantation and posterior corneal astigmatism exceeding 0.5 diopter were enrolled in this retrospective study.The keratometric astigmatism(KA) and total corneal astigmatism(TA) were measured using a Pentacam rotating Scheimpflug camera to assess the outcomes of AcrySof IOL implantation.Toric lOLs were evaluated in 26 eyes using KA measurements and in 31 eyes using TA measurements.Preoperative corneal astigmatism and postoperative refractive astigmatism were recorded for statistical analysis.The cylindrical power of toric lOLs was estimated in all eyes.RESULTS:In all cases,the difference of toric IOL astigmatism magnitude between KA and TA measurements for the estimation of preoperative corneal astigmatism was statistically significant.Of a total of 57 cases,the 50.88%decreased from Tn to Tn-1 and 10.53%decreased from Tn to Tn-2.In all cases,5.26%increased from Tn to Tn+1.The mean postoperative astigmatism within the TA group was significantly lower than that in the KA group.CONCLUSION:The accuracy of total corneal astigmatism calculations and the efficacy of toric IOL correction can be enhanced by measuring both the anterior and posterior corneal surfaces using a Pentacam rotating Scheimpflug camera.AIM:To evaluate the effects of posterior corneal surface measurements on the accuracy of total estimated corneal astigmatism.METHODS:Fifty-seven patients with toric intraocular lens(IOL) implantation and posterior corneal astigmatism exceeding 0.5 diopter were enrolled in this retrospective study.The keratometric astigmatism(KA) and total corneal astigmatism(TA) were measured using a Pentacam rotating Scheimpflug camera to assess the outcomes of AcrySof IOL implantation.Toric lOLs were evaluated in 26 eyes using KA measurements and in 31 eyes using TA measurements.Preoperative corneal astigmatism and postoperative refractive astigmatism were recorded for statistical analysis.The cylindrical power of toric lOLs was estimated in all eyes.RESULTS:In all cases,the difference of toric IOL astigmatism magnitude between KA and TA measurements for the estimation of preoperative corneal astigmatism was statistically significant.Of a total of 57 cases,the 50.88%decreased from Tn to Tn-1 and 10.53%decreased from Tn to Tn-2.In all cases,5.26%increased from Tn to Tn+1.The mean postoperative astigmatism within the TA group was significantly lower than that in the KA group.CONCLUSION:The accuracy of total corneal astigmatism calculations and the efficacy of toric IOL correction can be enhanced by measuring both the anterior and posterior corneal surfaces using a Pentacam rotating Scheimpflug camera.

关 键 词:CORNEA ASTIGMATISM CATARACT intraocular lenses refractive errors rotating Scheimpflug camera 

分 类 号:R779.66[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象