检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:LI Yanyan YIN Lei LI Yanhua SUN Zhihui ZHAO Xiaojun GAO Mingyue WANG Hongliang
机构地区:[1]The First Hospital of Jilin University, Changchun 130021, P. R. China [2]School of Life Science, Jilin University, Changchun 130012, R R. China
出 处:《Chemical Research in Chinese Universities》2017年第3期339-342,共4页高等学校化学研究(英文版)
基 金:Supported by the National Natural Science Foundation of China(Nos.81603182, 81430087, 81673396).
摘 要:A reliable liquid chromatography-tandem mass spectrometric(LC-MS/MS) method was developed and va- lidated for the simultaneous determination of vancomycin and voriconazole in human plasma. The analytes and internal standard 10-hydroxycarbazepine were separated at a flow rate of 0.9 mL/min using a Zorbax SB-C18 column (50 min×4.6 mm, 2.7 μm). Positive ion electrospray ionization was used to detect vancomycin, voriconazole and intrenal standard(IS) 10-hydroxycarbazepine followed by multiple reaction monitoring(MRM) of the transition at m/z 725.5→144.2, 350.3→281.0 and 253.1→208.0, respectively. The total run time for both vancomycin and voriconazole samples was 5 min; 0.30μg/mL was the lower limit of quantification. The precision of intraday and interday was no more than 12.4%. The method was successfully and resoundingly applied in therapeutic drug monitoring of 156 patients treated with vancomycin and voriconazole.A reliable liquid chromatography-tandem mass spectrometric(LC-MS/MS) method was developed and va- lidated for the simultaneous determination of vancomycin and voriconazole in human plasma. The analytes and internal standard 10-hydroxycarbazepine were separated at a flow rate of 0.9 mL/min using a Zorbax SB-C18 column (50 min×4.6 mm, 2.7 μm). Positive ion electrospray ionization was used to detect vancomycin, voriconazole and intrenal standard(IS) 10-hydroxycarbazepine followed by multiple reaction monitoring(MRM) of the transition at m/z 725.5→144.2, 350.3→281.0 and 253.1→208.0, respectively. The total run time for both vancomycin and voriconazole samples was 5 min; 0.30μg/mL was the lower limit of quantification. The precision of intraday and interday was no more than 12.4%. The method was successfully and resoundingly applied in therapeutic drug monitoring of 156 patients treated with vancomycin and voriconazole.
关 键 词:Liquid chromatography-tandem mass spectrometry(LC-MS/MS) VANCOMYCIN VORICONAZOLE Therapeutic drug monitoring
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3