作  者:胡卫朋 莫家国 梁才航[2] 李小良 李达显 HU Weipeng;MO Jiaguo;LIANG Caihang;LI Xiaoliang;LI Daxian(Guilin Branch,Guangxi Special Equipment Inspection and Research Institute,Guilin,Guangxi 541004,China;School of Mechanical & Electrical Engineering,Guilin University of Electronic Technology,Guilin,Guangxi 541004,China)

机构地区:[1]广西特种设备检验研究院桂林分院,广西桂林541004 [2]桂林电子科技大学机电工程学院,广西桂林541004

出  处:《中国科技论文》2018年第10期1177-1181,共5页China Sciencepaper

基  金:国家自然科学基金资助项目(51566002)

摘  要:本文研究了波节管换热器用于液体食品杀菌的可行性,分别对不同内管的套管式换热器用于海鲜酱杀菌过程中压降及传热性能进行实验研究和分析,并应用粒子群优化算法对波节管进行了结构优化。研究结果表明:在相同规格下,波节管换热器的单位压降是光管的1.5~2倍,传热性能比光管提高了25%~120%,在满足传热性能的条件下,优化后的波节管传热面积增加了61.85%。The feasibility of the corrugated tube heat exchanger used in liquid food sterilization was studied.The pressure drop and diathermancy of the double-pipe heat exchangers with different inner tubes for hoisin sauce sterilization were experimentally researched and analyzed.And the structure of the corrugated tube was optimized by Particle Swarm Optimization(PSO)algorithm.The results show that with the same volume,the unit pressure drop of the corrugated tube heat exchanger was 1.5-2 times of the smooth-tube heat exchanger,and the diathermancy is also improved by 25%-120%.The heat transfer area of the corrugated tube heat exchanger optimized by PSO is increased by 61.85%compared with the heat exchanger without optimization under the condition of the required heat transfer performance.

关 键 词:波节管换热器 海鲜酱 实验研究 粒子群算法 优化 

分 类 号:TK172[动力工程及工程热物理—热能工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象