Electrochemical determination of an anti-hyperlipidimic drug pitavastatin at electrochemical sensor based on electrochemically pre-treated polymer film modified GCE  被引量:1

Electrochemical determination of an anti-hyperlipidimic drug pitavastatin at electrochemical sensor based on electrochemically pre-treated polymer film modified GCE

在线阅读下载全文

作  者:Umar J.Pandit Gowhar A.Naikoo Mehraj Ud Din Sheikh Gulzar A.Khan K.K.Raj S.N.Limaye 

机构地区:[1]Department of Chemistry,Dr. Harisingh Gour University,Sagar,M.P.,India [2]Department of Mathematics and Sciences,College of Arts and Applied Sciences,Dofar University,Salalah,Oman

出  处:《Journal of Pharmaceutical Analysis》2017年第4期258-264,共7页药物分析学报(英文版)

摘  要:An electrochemically pretreated silver macroporous(Ag MP) multiwalled carbon nanotube modified glassy carbon electrode(PAN-Ag MP-MWCNT-GCE) was fabricated for the selective determination of an antihyperlipidimic drug, pitavastatin(PST). The fabricated electrochemical sensor was characterized by cyclic voltammetry(CV) and electrochemical impedance spectroscopy(EIS). The fabricated electrode was employed in quantifying and determining PST through differential pulse adsorptive stripping voltammetry(DPAdSV) and CV. The electrode fabrication proceeded with remarkable sensitivity to the determination of PST. The effect of various optimized parameters such as pH, scan rate(ν), accumulation time(t_(acc)), accumulation potential(U_(acc))and loading volumes of Ag MP-MWCNT suspension were investigated to evaluate the performance of synthesized electrochemical sensor and to propose a simple, accurate, rapid and economical procedure for the quantification of PST in pharmaceutical formulations and biological fluids. A linear response of PST concentration in the range 2.0×10^(-7)–1.6×10^(-6)M with low detection(LOD) and quantification(LOQ) limits of 9.66 ± 0.04 nM and 32.25 ± 0.07 nM, respectively, were obtained under these optimized conditions.An electrochemically pretreated silver macroporous(Ag MP) multiwalled carbon nanotube modified glassy carbon electrode(PAN-Ag MP-MWCNT-GCE) was fabricated for the selective determination of an antihyperlipidimic drug, pitavastatin(PST). The fabricated electrochemical sensor was characterized by cyclic voltammetry(CV) and electrochemical impedance spectroscopy(EIS). The fabricated electrode was employed in quantifying and determining PST through differential pulse adsorptive stripping voltammetry(DPAdSV) and CV. The electrode fabrication proceeded with remarkable sensitivity to the determination of PST. The effect of various optimized parameters such as pH, scan rate(ν), accumulation time(t_(acc)), accumulation potential(U_(acc))and loading volumes of Ag MP-MWCNT suspension were investigated to evaluate the performance of synthesized electrochemical sensor and to propose a simple, accurate, rapid and economical procedure for the quantification of PST in pharmaceutical formulations and biological fluids. A linear response of PST concentration in the range 2.0×10^(-7)–1.6×10^(-6)M with low detection(LOD) and quantification(LOQ) limits of 9.66 ± 0.04 nM and 32.25 ± 0.07 nM, respectively, were obtained under these optimized conditions.

关 键 词:PITAVASTATIN Electrochemical sensor ADSORPTIVE STRIPPING VOLTAMMETRY Biological fluids PHARMACEUTICAL formulations 

分 类 号:R914[医药卫生—药物化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象