基于卡尔曼滤波和加权LM法的井下精确定位算法  被引量:6

Underground precise positioning algorithm based on Kalman filter and weighted LM algorithm

在线阅读下载全文

作  者:王伟 WANG Wei(CCTEG Changzhou Research Institute,Changzhou 213015,China;Tiandi(Changzhou)Automation Co.,Ltd.,Changzhou 213015,China)

机构地区:[1]中煤科工集团常州研究院有限公司 [2]天地(常州)自动化股份有限公司

出  处:《工矿自动化》2019年第11期5-9,共5页Journal Of Mine Automation

基  金:中国煤炭科工集团有限公司青年项目(2018QN028);中国煤炭科工集团科技创新基金重点项目(2018-TD-ZD005);中国煤炭科工集团有限公司双创项目(2018-TD-MS013)

摘  要:针对基于UWB精确定位的井下近感检测装置定位结果易受非视距(NLOS)误差等噪声影响的问题,提出了一种基于卡尔曼滤波和加权LM法的井下精确定位算法。通过卡尔曼滤波预测过程得到标签卡坐标的先验估计值;利用几何关系计算估计坐标与各锚节点的距离,并将该距离与探测器直接测距值进行比较,根据差值分配各锚节点的测距权值;将权值矩阵和测距矩阵代入加权LM法中,得到标签卡坐标的中间结果;将中间结果作为测量值代入卡尔曼滤波更新过程中,得到标签卡的最终坐标。测试结果表明,与多边定位法相比,基于卡尔曼滤波和加权LM法的井下精确定位算法可在不影响定位速度的前提下,将定位精度提高一倍以上,有效降低了NLOS误差等噪声的干扰。In view of problem that positioning result of underground proximity detection device based on UWB precise positioning is susceptible to noise such as non-line of sight(NLOS)error,an underground precise positioning algorithm based on Kalman filter and weighted LM algorithm was proposed.Priori estimation value of tag card coordinates is obtained by Kalman filter prediction process;distance between the estimatied coordinates and each anchor node is calculated by using geometric relationship,the calculated distance is compared with direct measuring value of the detector,and ranging weight of each anchor node is allocated according to difference of the calculated distance and measured distance;weight matrix and ranging matrix are substituted into the weighted LM algorithm as the measured value to obtain intermediate result of the tag card coordinates;the intermediate result is substituted into Kalman filter update process to obtain final coordinates of the tag card.The test results show that compared with the multilateral positioning method,the underground precise positioning algorithm based on Kalman filter and weighted LM algorithm can improve positioning accuracy by more than one time without affecting positioning speed,and effectively reducing the interference of NLOS error and other noises.

关 键 词:井下精确定位 近感检测装置 超宽带精确定位 锚节点 卡尔曼滤波 加权LM法 NLOS误差 

分 类 号:TD655.3[矿业工程—矿山机电]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象