作 者:Yingying Dai Shaodan Zhang Meixiao Shen Yuheng Zhou Mengyi Wang Jie Ye Dexi Zhu
机构地区:[1]School of Ophthalmology and Optometry,Wenzhou Medical University,Wenzhou,Zhejang,China
出 处:《Eye and Vision》2022年第4期10-19,共10页眼视光学杂志(英文)
基 金:Supported by research grants from the Natural Science Foundation of Zhejang Province(Grant No.LY18H180008);Optometry Engineering Technology Development Project of Zheijang Eye Hospital(Grant No.GCKF201603).
摘 要:Background:To quantitatively assess anterior chamber angle(ACA)structure by anterior segment optical coherence tomography(AS-ocT)and develop a model to evaluate angle width as defined by gonioscopy.Methods:The ACAs of each quadrant were evaluated by gonioscopy,classified by the Scheie grading system,and assigned into one of the three grades:small angle(SA),moderate angle(MA),and large angle(LA).The eyes were imaged by AS-OCT,and ACA structural parameters including angle opening distance at the scleral spur(AODSS)and at 750μm anterior to the scleral spur(AOD750),trabecular-iris space area at 750μm anterior to the scleral spur(TISA750),and a newly defined parameter"light intersection distance"(LID),were measured.The ACA structural data were used to construct an ordered logistic regression model for assignment of ACAs to one of the three angle grades.The validity of the model was then tested.Results:A total of 169 quadrants from 53 subjects were included in the analysis,of which 111 quadrants were included in the modeling data and 58 in the testing data.In pairwise comparisons of SA,MA,and LA by ANOVA,the measured parameters were as follows:AOD750(0.174±0.060 vs.0.249±0.068 vs.0.376±0.114 mm;P<0.001),TISA750(0.075±0.035 vs.0.117±0.036 vs.0.181±0.062 mm^(2);P<0.001),and LID(0.300±0.187 vs.0.085±0.170 vs.0.122±0.156 mm;P<0.001).The ACA grading model based on LID showed a relatively high correction rate of 72.4%,and the model efficiency,calculated using the receiver operating characteristic,showed an area under the curve of 0.740.Weighted kappa statistics showed a good agreement for multiple ACA grades(0.772).Conclusions:The AS-OCT-based multiple ACA grades model was demonstrated as a non-contact approach for ACA assessment with high speed and high spatial resolution,providing guidance for diagnosis of angle closure.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15