Ahmed glaucoma implant and augmented MicroPulse transscleral cyclophotocoagulation in a monocular Axenfeld-Rieger syndrome patient with glaucoma  

在线阅读下载全文

作  者:Sanchay Gupta Amy Yuan Marika Chachanidze David A.Solá-Del Valle 

机构地区:[1]Harvard Medical School,Boston,MA 02115,USA [2]Glaucoma Service,Massachusetts Eye and Ear Infirmary,Boston,MA 02114,USA

出  处:《International Journal of Ophthalmology(English edition)》2022年第10期1714-1716,共3页国际眼科杂志(英文版)

摘  要:Dear Editor,We report the case of severe mixed-mechanism glaucoma observed in a monocular Axenfeld-Rieger syndrome(ARS) patient who was successfully managed with an ahmed glaucoma implant(AGI) followed by a novel technique described as augmented Micro Pulse transscleral cyclophotocoagulation(MP-TSCPC)[1]. ARS encompasses a heterogeneous spectrum of diseases involving anterior segment dysgenesis and systemic developmental anomalies[2].

关 键 词:GLAUCOMA PATIENT IMPLANT 

分 类 号:R775[医药卫生—眼科]

 