基于频率切换的LCC-S型IPT系统恒流/恒压输出研究  

Research on Constant Current/Constant Voltage Output of LCC-S IPT System Based on Frequency Switching

在线阅读下载全文

作  者:熊明星 张皓钧 周芸如 杨泽伟 丁宁[3] 李伟华[1,2] XIONG Mingxing;ZHANG Haojun;ZOU Yunru;YANG Zewei;DING Ning;LI Weihua(Institute of Rail Transit,Jinan University,Zhuhai Guangdong 519000,China;School of International Energy,Jinan University,Zhuhai Guangdong 519000,China;School of Intelligent Systems Science and Engineering,Jinan University,Zhuhai Guangdong 519000,China)

机构地区:[1]暨南大学轨道交通研究院,广东珠海519000 [2]暨南大学国际能源学院,广东珠海519000 [3]暨南大学智能科学与工程学院,广东珠海519000

出  处:《电子器件》2023年第4期984-990,共7页Chinese Journal of Electron Devices

基  金:2022年国家级大学生创新创业训练计划项目(202210559107);2021年广东省大学生创新创业训练计划项目(S202110559064)2022-11-11 2023-02-01。

摘  要:为实现感应电能传输(Inductive Power Transfer,IPT)系统在变负载条件下的恒流/恒压高效输出,提出一种基于频率切换的LCC-S型IPT系统参数配置及优化方法。从LCC-S补偿拓扑入手,分别得到系统恒流或恒压零相位角(Zero Phase Angle,ZPA)输出的条件方程,并推导了电流增益、电压增益与系统参数之间的定量关系;进一步通过定义系统的输出增益比,分析了恒流/恒压模式下输出增益、负载电阻与整体效率的关系;在此基础上,通过选取最佳的输出增益值,使得系统整体效率达到了全局最大化。仿真结果表明,负载电阻在3~300Ω的变化范围内包括恒流/恒压模式切换瞬间都能保持稳定的输出,并且恒流/恒压模式下均能实现ZPA运行,同时系统整体效率都维持在90%以上。To achieve constant current/constant voltage high-efficiency output of inductive power transmission(IPT)system under variable load conditions,a parameter configuration and optimization method of LCC-S IPT system based on frequency switching is proposed.Starting with LCC-S compensation topology,the conditional equations of zero phase angle output at the constant current or constant voltage are obtained respectively,and the quantitative relationship between current gain,voltage gain,and system parameters is derived.Further-more,by defining the output gain ratio of the system,the relationship between the output gain,load resistance and the overall efficiency in the constant current/constant voltage mode is analyzed.On this basis,the overall efficiency of the system is maximized by selecting the op-timal output gain value.The simulation results show that the load resistance can maintain a stable output in the range of 3~300Ω,inclu-ding the instant of constant current/constant voltage mode switching,and ZPA operation can be achieved under constant current/constant voltage mode,while the overall efficiency of the system is maintained above 90%.

关 键 词:感应电能传输 LCC-S 恒流/恒压 输出增益比 参数优化 

分 类 号:TN724[电子电信—电路与系统]

 