检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:余小娜[1] 苏趁意 YU Xiaona;SU Chenyi(Food and Pharmacy College,Xuchang University,Xuchang 461000,China)
出 处:《许昌学院学报》2023年第5期58-61,共4页Journal of Xuchang University
基 金:河南省大学生创新创业项目(S202210480043)。
摘 要:将热还原石墨烯和铁氰化镍(NiHCF)颗粒经超声分散后得到NiHCF/石墨烯复合物,采用扫描电子显微镜、傅里叶红外等技术表征了石墨烯及石墨烯复合物的形貌及特征结构.利用循环伏安法考察了NiHCF/石墨烯膜电极的电化学行为.结果表明,该材料具有优异的电子传递性能.采用计时电流测试技术实现了对抗坏血酸的定量检测,在1×10^(-4)~7×10^(-4)mol·L^(-1)浓度范围内,响应电流和分析物浓度之间呈现良好的线性关系.该NiHCF/石墨烯膜电极有望用于实际样品中抗坏血酸的灵敏、快速检测.NiHCF/Graphene composites were prepared by ultrasonic dispersion of thermally reduced Graphene and nickel hexacyanoferrate(NiHCF)particles.The morphology and characteristic structure of Graphene and Graphene composites were characterized by scanning electron microscope and fourier infrared spectroscopy.The electrochemical behavior NiHCF/Graphene film electrode was investigated by Cyclic voltammetry.The experimental results indicate that the composite material has excellent electronic conductivity.Quantitative detection of ascorbic acid was achieved using i-t testing technology on film electrode.Within the concentration range of 1×10^(-4)~7×10^(-4)mol·L^(-1),there is a good linear relationship between the response current and the analyte concentration.The NiHCF/Graphene membrane electrode is expected to be used for the sensitive and rapid determination of ascorbic acid in actual samples.