检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Tairo Kashihara Yuka Urago Hiroyuki Okamoto Mihiro Takemori Hiroki Nakayama Shohei Mikasa Tetsu Nakaichi Kotaro Iijima Takahito Chiba Junichi Kuwahara Satoshi Nakamura Weishan Chang Yoshiyuki Matsui Hiroshi Igaki
机构地区:[1]Department of Radiation Oncology,National Cancer Center Hospital,5-1-1 Tsukiji,Chuo-ku,Tokyo,Japan [2]Radiation Safety and Quality Assurance Division,National Cancer Center Hospital,5-1-1 Tsukiji,Chuo-ku,Tokyo,Japan [3]Department of Radiological Sciences,Graduate School of Human Health Sciences,Tokyo Metropolitan University,7-2-10 Higashi-Ogu,Arakawa-ku,Tokyo,Japan [4]Department of Radiological Technology,National Cancer Center Hospital,5-1-1 Tsukiji,Chuo-ku,Tokyo,Japan [5]Department of Urological Oncology,National Cancer Center Hospital,5-1-1 Tsukiji,Chuo-ku,Tokyo,Japan
出 处:《Asian Journal of Urology》2024年第2期286-293,共8页亚洲泌尿外科杂志(英文)
摘 要:Objectives: Hydrogel spacer (HS) was developed to reduce rectal toxicities caused by radiotherapy, but has been reported to cause major adverse events. Our institute has attempted to introduce a hyaluronic acid (HA) as an alternative spacer. This study aimed to compare rectal doses and geometric distributions between the HS and HA implantation in prostate cancer.Methods: HS and HA were inserted in 20 and 18 patients undergoing high-dose brachytherapy, respectively. The rectum spacer volumes injected were 10 mL and 22 mL, respectively. In the treatment planning system, 13.5 Gy was administered with common catheter positions. The rectal dose indices were assessed between the spacer groups for dosimetry evaluation. Distances between the prostate and rectum and configurations of the spacers were compared.Results: The mean doses irradiated to 0.1 and 2 mL of the rectum were 10.45 Gy and 6.71 Gy for HS, and 6.73 Gy and 4.90 Gy for HA (p<0.001). The mean minimum distances between the prostate and rectum were 1.23 cm and 1.79 cm for HS and HA, respectively (p<0.05). Geometrical configuration comparisons revealed that HA has a higher ability to expand the space than HS.Conclusion: The rectal dose reduction ability of HA is significantly greater than that of HS, suggesting its potential as a new spacer.
关 键 词:BRACHYTHERAPY Hyaluronicacid HYDROGEL Prostaticneoplasm RADIOTHERAPY
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7