Relationship between short-wavelength automatic perimetry and Heidelberg retina tomograph parameters in eyes with ocular hypertension  被引量:1

Relationship between short-wavelength automatic perimetry and Heidelberg retina tomograph parameters in eyes with ocular hypertension

在线阅读下载全文

作  者:Christos Pitsas Dimitrios Papaconstantinou Ilias Georgalas Ioannis Halkiadakis 

机构地区:[1]Department of Ophthalmology,Medical School,University of Athens Georgos Gennimatas Hospital [2]Ophthalmiatrion Athinon,Athens Eye Hospital

出  处:《International Journal of Ophthalmology(English edition)》2015年第5期1013-1017,共5页国际眼科杂志(英文版)

摘  要:AIMTo compare and correlate optic nerve head parameters obtained by Heidelberg retina tomograph (HRT) with short-wavelength automatic perimetry (SWAP) indices in eyes with ocular hypertension (OHT).METHODSOne hundred and forty-six patients with OHT included in the present study. All subjects had reliable SWAP and HRT measurements performed within a 2wk period. The eyes were classified as normal/abnormal according to visual field criteria and Moorfields regression analysis (MRA). Correlations between visual field indices and HRT parameters were analyzed using Pearson correlation coefficient (r).RESULTSTwenty-nine eyes (19.9%) had SWAP defects. Twenty-nine eyes (19.9%) were classified as abnormal according to global MRA. Six eyes (4.1%) had abnormal global MRA and SWAP defects. The k statistic is 0.116 (P=0.12) indicating a very poor agreement between the methods. No statistical significant correlation between HRT and SWAP parameters was detected.CONCLUSIONSWAP defects may coexist with abnormalities of optic disc detected by HRT in eyes with OHT. In most eyes, however, the two methods detect different glaucoma properties.AIMTo compare and correlate optic nerve head parameters obtained by Heidelberg retina tomograph (HRT) with short-wavelength automatic perimetry (SWAP) indices in eyes with ocular hypertension (OHT).METHODSOne hundred and forty-six patients with OHT included in the present study. All subjects had reliable SWAP and HRT measurements performed within a 2wk period. The eyes were classified as normal/abnormal according to visual field criteria and Moorfields regression analysis (MRA). Correlations between visual field indices and HRT parameters were analyzed using Pearson correlation coefficient (r).RESULTSTwenty-nine eyes (19.9%) had SWAP defects. Twenty-nine eyes (19.9%) were classified as abnormal according to global MRA. Six eyes (4.1%) had abnormal global MRA and SWAP defects. The k statistic is 0.116 (P=0.12) indicating a very poor agreement between the methods. No statistical significant correlation between HRT and SWAP parameters was detected.CONCLUSIONSWAP defects may coexist with abnormalities of optic disc detected by HRT in eyes with OHT. In most eyes, however, the two methods detect different glaucoma properties.

关 键 词:GLAUCOMA PERIMETRY optic disc ocular hypertension 

分 类 号:R775[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象