作 者:Christos Pitsas Dimitrios Papaconstantinou Ilias Georgalas Ioannis Halkiadakis
机构地区:[1]Department of Ophthalmology,Medical School,University of Athens Georgos Gennimatas Hospital [2]Ophthalmiatrion Athinon,Athens Eye Hospital
出 处:《International Journal of Ophthalmology(English edition)》2015年第5期1013-1017,共5页国际眼科杂志(英文版)
摘 要:AIMTo compare and correlate optic nerve head parameters obtained by Heidelberg retina tomograph (HRT) with short-wavelength automatic perimetry (SWAP) indices in eyes with ocular hypertension (OHT).METHODSOne hundred and forty-six patients with OHT included in the present study. All subjects had reliable SWAP and HRT measurements performed within a 2wk period. The eyes were classified as normal/abnormal according to visual field criteria and Moorfields regression analysis (MRA). Correlations between visual field indices and HRT parameters were analyzed using Pearson correlation coefficient (r).RESULTSTwenty-nine eyes (19.9%) had SWAP defects. Twenty-nine eyes (19.9%) were classified as abnormal according to global MRA. Six eyes (4.1%) had abnormal global MRA and SWAP defects. The k statistic is 0.116 (P=0.12) indicating a very poor agreement between the methods. No statistical significant correlation between HRT and SWAP parameters was detected.CONCLUSIONSWAP defects may coexist with abnormalities of optic disc detected by HRT in eyes with OHT. In most eyes, however, the two methods detect different glaucoma properties.AIMTo compare and correlate optic nerve head parameters obtained by Heidelberg retina tomograph (HRT) with short-wavelength automatic perimetry (SWAP) indices in eyes with ocular hypertension (OHT).METHODSOne hundred and forty-six patients with OHT included in the present study. All subjects had reliable SWAP and HRT measurements performed within a 2wk period. The eyes were classified as normal/abnormal according to visual field criteria and Moorfields regression analysis (MRA). Correlations between visual field indices and HRT parameters were analyzed using Pearson correlation coefficient (r).RESULTSTwenty-nine eyes (19.9%) had SWAP defects. Twenty-nine eyes (19.9%) were classified as abnormal according to global MRA. Six eyes (4.1%) had abnormal global MRA and SWAP defects. The k statistic is 0.116 (P=0.12) indicating a very poor agreement between the methods. No statistical significant correlation between HRT and SWAP parameters was detected.CONCLUSIONSWAP defects may coexist with abnormalities of optic disc detected by HRT in eyes with OHT. In most eyes, however, the two methods detect different glaucoma properties.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.139.239.16