Assessing XEN microstent’s one-year efficacy:independent of site variability  

在线阅读下载全文

作  者:Caroline Bormann Catharina Busch Matus Rehak Christian Thomas Scharenberg Focke Ziemssen Jan Darius Unterlauft 

机构地区:[1]Department of Ophthalmology,University of Leipzig,Liebigstrasse 10-14,Leipzig 04103,Germany [2]Department of Ophthalmology,University of Innsbruck,AnichstraBe 35,Innsbruck 6020,Austria [3]Smile Eyes Augen-und Laserzentrum Leipzig,LampestraBe 1,Leipzig 04107,Germany [4]Department of Ophthalmology,Inselspital,University of Bern,Freiburgstrasse 4,Bern 3010,Switzerland

出  处:《International Journal of Ophthalmology(English edition)》2025年第1期86-93,共8页国际眼科杂志(英文版)

基  金:Funded by the Open Access Publishing Fund of Leipzig University supported by the German Research Foundation within the program Open Access.

摘  要:AIM:To evaluate the short-term efficacy of XEN45 Gel Stent(XEN)implantation for primary open angle glaucoma(POAG)and pseudoexfoliation(PEX)glaucoma across two university eye clinics,aiming to assess the impact of varying center-specific protocols during the first postoperative year.METHODS:We retrospectively examined 282 patients(183 in center 1,99 in center 2),who underwent XEN microstent implantation for uncontrolled POAG or PEX glaucoma.Parameters including intraocular pressure(IOP),IOP-lowering medication count,best corrected visual acuity(BCVA),and postoperative complications were evaluated over 12mo.RESULTS:Post-implantation,center 1 reported a mean IOP reduction from 25.3±7.4 to 14.1±4.7 mm Hg(P<0.01)and a decrease in IOP-lowering medications from 3.2±1.2 to 1.0±1.3(P<0.01).Center 2 observed a similar reduction from 24.4±6.5 to 15.1±5.5 mm Hg(P<0.01)and medication decrease from 3.0±1.1 to 1.2±1.0(P<0.01).BCVA remained stable in both cohorts.The most common complications were hypotony(center 1:32;center 2:20)and choroidal detachment(center 1:22,center 2:15),with nearly identical needling rates(40% in center 1,41% in center 2).CONCLUSION:XEN implantation yields consistent reductions in IOP and medication use across different centers using comparable surgical and postoperative treatment regime.These findings underscore XEN’s shortterm effectiveness and suggest standardizable outcomes regardless of exact surgical procedure or treatment differences.

关 键 词:GLAUCOMA XEN45 Gel Stent minimally invasive glaucoma surgery 

分 类 号:R779.6[医药卫生—眼科]

 