Enhancement of Tumor Regression by Coulomb Nanoradiator Effect in Proton Treatment of Iron-Oxide Nanoparticle-Loaded Orthotopic Rat Glioma Model: Implication of Novel Particle Induced Radiation Therapy  

Enhancement of Tumor Regression by Coulomb Nanoradiator Effect in Proton Treatment of Iron-Oxide Nanoparticle-Loaded Orthotopic Rat Glioma Model: Implication of Novel Particle Induced Radiation Therapy

在线阅读下载全文

作  者:Seung-Jun Seo Jae-Kun Jeon Eun-Ju Jeong Won-Seok Chang Gi-Hwan Choi Jong-Ki Kim 

机构地区:[1]Department of Biomedical Engineering, School of Medicine, Catholic University of Daegu, 3056-6 Taemyung 4 Dong, Nam-Ku, Daegu City, South Korea [2]Department of Diagnostic Imaging, School of Medicine, Catholic University of Daegu, 3056-6 Taemyung 4 Dong, Nam-Ku, Daegu City, South Korea [3]Department of Neurosurgery, School of Medicine, Catholic University of Daegu, 3056-6 Taemyung 4 Dong, Nam-Ku, Daegu City, South Korea

出  处:《Journal of Cancer Therapy》2013年第11期25-32,共8页癌症治疗(英文)

摘  要:Background: Proton-impact metallic nanoparticles, inducing low-energy electrons emission and characteristic X-rays termed as Coulomb nanoradiator effect (CNR), are known to produce therapeutic enhancement in proton treatment on experimental tumors. The purpose of this pilot study was to investigate the effect of CNR-based dose enhancement on tumor growth inhibition in an iron-oxide nanoparticle (FeONP)-loaded orthotopic rat glioma model. Methods: Proton-induced CNR was exploited to treat glioma-bearing SD rat loaded with FeONP by either fully-absorbed single pristine Bragg peak (APBP) or spread-out Bragg peak (SOBP) 45-MeV proton beam. A selected number of rats were examined by MRI before and after treatment to obtain the size and position information for adjusting irradiation field. Tumor regression assay was performed by histological analysis of residual tumor in the sacrificed rats 7 days after treatment. The results of CNR-treated groups were compared with the proton alone control. Results: Intravenous injection of FeONP (300 mg/kg) elevated the tumor concentration of iron up to 37 μg of Fe/g tissue, with a tumor-to-normal ratio of 5, 24 hours after injection. The group receiving FeONP and proton beam showed 65% - 79% smaller tumor volume dose-dependently compared with the proton alone group. The rats receiving FeONP and controlled irradiation field by MR imaging demonstrated more than 95% - 99% tumor regression compared with MRI-determined initial tumor size. Conclusions: Proton-impact FeONP produced therapeutic enhancement compared with proton alone in an orthotopic rat glioma model at a selected temporal point after treatment. Single BP proton beam could induce CNR- based dose enhancement and produce enhanced tumor regression that was comparable to SOBP treatment despite inhomogeneous tumor dose in the APBP-treated tumor. These results may suggest emergence of novel Particle Induced Radiation Therapy (PIRT) on malignant glioma.Background: Proton-impact metallic nanoparticles, inducing low-energy electrons emission and characteristic X-rays termed as Coulomb nanoradiator effect (CNR), are known to produce therapeutic enhancement in proton treatment on experimental tumors. The purpose of this pilot study was to investigate the effect of CNR-based dose enhancement on tumor growth inhibition in an iron-oxide nanoparticle (FeONP)-loaded orthotopic rat glioma model. Methods: Proton-induced CNR was exploited to treat glioma-bearing SD rat loaded with FeONP by either fully-absorbed single pristine Bragg peak (APBP) or spread-out Bragg peak (SOBP) 45-MeV proton beam. A selected number of rats were examined by MRI before and after treatment to obtain the size and position information for adjusting irradiation field. Tumor regression assay was performed by histological analysis of residual tumor in the sacrificed rats 7 days after treatment. The results of CNR-treated groups were compared with the proton alone control. Results: Intravenous injection of FeONP (300 mg/kg) elevated the tumor concentration of iron up to 37 μg of Fe/g tissue, with a tumor-to-normal ratio of 5, 24 hours after injection. The group receiving FeONP and proton beam showed 65% - 79% smaller tumor volume dose-dependently compared with the proton alone group. The rats receiving FeONP and controlled irradiation field by MR imaging demonstrated more than 95% - 99% tumor regression compared with MRI-determined initial tumor size. Conclusions: Proton-impact FeONP produced therapeutic enhancement compared with proton alone in an orthotopic rat glioma model at a selected temporal point after treatment. Single BP proton beam could induce CNR- based dose enhancement and produce enhanced tumor regression that was comparable to SOBP treatment despite inhomogeneous tumor dose in the APBP-treated tumor. These results may suggest emergence of novel Particle Induced Radiation Therapy (PIRT) on malignant glioma.

关 键 词:PROTON Therapy Iron Oxide Nanoparticles COULOMB Nanoradiator MALIGNANT GLIOMA 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象