检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Osman A. Hameed[1] Hussam Mustafa[1] Abdul Fatah M. Ahmed[1] Mohamed Khidr Taha[1]
出 处:《Open Journal of Veterinary Medicine》2019年第12期194-201,共8页兽医学(英文)
摘 要:IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hours, 7 days and 14 days after birth showed level of IgG 1000 mg/dl. This level indicated that they have good passive transfer of immunity. Also, in this study colostrum quality fed to calves was detected using Brix Refractometer. The colostrum is of high quality as it contains 50 mg/ml of IgG. This Brix refractometer can be used on the farm level to estimate colostrum IgG content and monitoring colostrum feeding practices. Colostrum with high quality IgG could provide calves with enough IgG to attain successful passive transfer of immunity. Brix and Obione refractometers provide simple, rapid method for estimating IgG concentration on calf serum, thus considered to be the most common method for determining passive transfer failure.IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hours, 7 days and 14 days after birth showed level of IgG 1000 mg/dl. This level indicated that they have good passive transfer of immunity. Also, in this study colostrum quality fed to calves was detected using Brix Refractometer. The colostrum is of high quality as it contains 50 mg/ml of IgG. This Brix refractometer can be used on the farm level to estimate colostrum IgG content and monitoring colostrum feeding practices. Colostrum with high quality IgG could provide calves with enough IgG to attain successful passive transfer of immunity. Brix and Obione refractometers provide simple, rapid method for estimating IgG concentration on calf serum, thus considered to be the most common method for determining passive transfer failure.
关 键 词:COLOSTRUM Passive IMMUNITY Immunoglobulin G (IgG) Failure of Transfer IMMUNITY (FTPI) Radial Immunodiffusion (RID) Turbidimetric IMMUNOASSAY (TA) REFRACTOMETER (REF) BRIX REFRACTOMETER (Brix) Obione REFRACTOMETER (Obione) IGG Check Calf IMMUNOASSAY High Quality COLOSTRUM Inadequate Transfer of Passive IMMUNITY (ITPI)
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7