Determination of Seven Volatile N-Nitrosamines in Fast Food  被引量:6

在线阅读下载全文

作  者:Mohammad Al-Kaseem Zaid Al-Assaf François Karabeet 

机构地区:[1]Department of Analytical and Food Chemistry,Faculty of Pharmacy,Damascus University,Damascus,Syria [2]Department of Chemistry,Faculty of Science,Damascus University,Damascus,Syria

出  处:《Pharmacology & Pharmacy》2014年第2期195-203,共9页药理与制药(英文)

摘  要:In this study, various fast food samples, including raw meat, cured meat, grilled meat, fried meat, smoked meat and canned meat products, were analyzed for the determination of the seven volatile N-nitrosamines. The samples were treated with an aqueous sodium hydroxide (NaOH) by autoclaving at 121°C for 10 min and extracted by liquid-liquid extraction with dichloromethane, and then the nitrosamines were pre-concentrated by using activated silica. Then, gas chromatography coupled with flame ionization detector was used for the separation and determination of the different nitrosamines contained in a real sample. The applied method allowed the determination of nitrosamine compounds at trace levels with limit of detection ranging from 0.077 to 0.18 ppb, and quantitation limits were from 0.26 to 0.60 ppb for all nitrosamines. The total concentrations of the seven nitrosamines in the studied meat samples ranged from 2.60 to 13.28 μg/kg.In this study, various fast food samples, including raw meat, cured meat, grilled meat, fried meat, smoked meat and canned meat products, were analyzed for the determination of the seven volatile N-nitrosamines. The samples were treated with an aqueous sodium hydroxide (NaOH) by autoclaving at 121°C for 10 min and extracted by liquid-liquid extraction with dichloromethane, and then the nitrosamines were pre-concentrated by using activated silica. Then, gas chromatography coupled with flame ionization detector was used for the separation and determination of the different nitrosamines contained in a real sample. The applied method allowed the determination of nitrosamine compounds at trace levels with limit of detection ranging from 0.077 to 0.18 ppb, and quantitation limits were from 0.26 to 0.60 ppb for all nitrosamines. The total concentrations of the seven nitrosamines in the studied meat samples ranged from 2.60 to 13.28 μg/kg.

关 键 词:GC-FID N-NITROSAMINES Fast Food MEAT AUTOCLAVE 

分 类 号:O6[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象