Comparison of Different Reconstruction Algorithms for Decreasing the Exposure Dose during Digital Breast Tomosynthesis: A Phantom Study  

Comparison of Different Reconstruction Algorithms for Decreasing the Exposure Dose during Digital Breast Tomosynthesis: A Phantom Study

在线阅读下载全文

作  者:Tsutomu Gomi 

机构地区:[1]School of Allied Health Sciences, Kitasato University, Sagamihara, Japan

出  处:《Journal of Biomedical Science and Engineering》2015年第8期471-478,共8页生物医学工程(英文)

摘  要:We compared reconstruction algorithms [filtered back projection (FBP), maximum likelihood expectation maximization (MLEM), and the simultaneous iterative reconstruction technique (SIRT)] in terms of the radiation dose and image quality, for exploring the possibility of decreasing the radiation dose during digital breast tomosynthesis (DBT). The three algorithms were implemented using a DBT system and experimentally evaluated using measurements, such as signal difference-to-noise ratio (SDNR) and intensity profile, on a BR3D phantom (infocus plane image). The possible radiation dose reduction, contrast improvement, and artifact reduction in DBT were evaluated using different exposure levels and the three reconstruction techniques. We performed statistical analysis (one-way analysis of variance) of the SDNR data. The effectiveness of each technique for enhancing the visibility of the BR3D phantom was quantified with regard to SDNR (FBP versus MLEM, P < 0.05;FBP vs. SIRT, P < 0.05;MLEM vs. SIRT, P = 0.945);the artifact reduction was quantified with regard to the intensity profile. MLEM and SIRT produced reconstructed images with SDNR values indicative of low-contrast visibility. The SDNR value for the half-radiation dose MLEM and SIRT images was close to that of the FBP reference radiation dose image. Artifacts were decreased in the MLEM and SIRT images (in the infocus plane) according to the intensity profiles that we obtained. With MLEM and SIRT, the radiation dose may be decreased to half comparison with FBP.We compared reconstruction algorithms [filtered back projection (FBP), maximum likelihood expectation maximization (MLEM), and the simultaneous iterative reconstruction technique (SIRT)] in terms of the radiation dose and image quality, for exploring the possibility of decreasing the radiation dose during digital breast tomosynthesis (DBT). The three algorithms were implemented using a DBT system and experimentally evaluated using measurements, such as signal difference-to-noise ratio (SDNR) and intensity profile, on a BR3D phantom (infocus plane image). The possible radiation dose reduction, contrast improvement, and artifact reduction in DBT were evaluated using different exposure levels and the three reconstruction techniques. We performed statistical analysis (one-way analysis of variance) of the SDNR data. The effectiveness of each technique for enhancing the visibility of the BR3D phantom was quantified with regard to SDNR (FBP versus MLEM, P < 0.05;FBP vs. SIRT, P < 0.05;MLEM vs. SIRT, P = 0.945);the artifact reduction was quantified with regard to the intensity profile. MLEM and SIRT produced reconstructed images with SDNR values indicative of low-contrast visibility. The SDNR value for the half-radiation dose MLEM and SIRT images was close to that of the FBP reference radiation dose image. Artifacts were decreased in the MLEM and SIRT images (in the infocus plane) according to the intensity profiles that we obtained. With MLEM and SIRT, the radiation dose may be decreased to half comparison with FBP.

关 键 词:Digital BREAST TOMOSYNTHESIS THREE-DIMENSIONAL Reconstruction RADIATION DOSE 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象