Rapid HPLC Method for Monitoring Relevant Residues of Pharmaceuticals Products in Environmental Samples  

在线阅读下载全文

作  者:Juana Rodriguez Flores Ana Maria Contento Salcedo Lorena Munoz Fernandez 

机构地区:[1]Department of Analytical Chemistry and Foods Technology,University of Castilla-La Mancha,Ciudad Real,Spain

出  处:《American Journal of Analytical Chemistry》2011年第1期18-26,共9页美国分析化学(英文)

摘  要:This work presents a multi-residue analytical method based on solid phase extraction (SPE) followed by high-performance liquid chromatographic (HPLC) with diode array (DAD) detection for the simultaneous determination of a group of pharmaceutical products that include ten antidepressants and three anticanceri- genic in environmental samples (water and soil). Baseline separation of the studied compounds was obtained on an ultrabase C18 (4.6 mm i.d. × 150 mm, 5 μm particle) column using acetonitrile:phosphate buffer pH 2.5 (35:65 v/v) as mobile phase with a flow rate of 1.5 mL/min. Different aspects including linearity, accuracy, precision and detection and quantification limits were examined in order to validate the proposed method. Detection limits between 1 and 50 ng/mL were obtained for all the target compounds. This method was ap- plied to the analysis of environmental samples as waters and soils of different precedence. Prior, the HPLC determination the samples were purified and enriched using SPE or liquid-liquid extraction (LLE) of the tar- get compounds.This work presents a multi-residue analytical method based on solid phase extraction (SPE) followed by high-performance liquid chromatographic (HPLC) with diode array (DAD) detection for the simultaneous determination of a group of pharmaceutical products that include ten antidepressants and three anticanceri- genic in environmental samples (water and soil). Baseline separation of the studied compounds was obtained on an ultrabase C18 (4.6 mm i.d. × 150 mm, 5 μm particle) column using acetonitrile:phosphate buffer pH 2.5 (35:65 v/v) as mobile phase with a flow rate of 1.5 mL/min. Different aspects including linearity, accuracy, precision and detection and quantification limits were examined in order to validate the proposed method. Detection limits between 1 and 50 ng/mL were obtained for all the target compounds. This method was ap- plied to the analysis of environmental samples as waters and soils of different precedence. Prior, the HPLC determination the samples were purified and enriched using SPE or liquid-liquid extraction (LLE) of the tar- get compounds.

关 键 词:High-Performance Liquid Chromatographic(HPLC) Breast Cancer ANTIDEPRESSANT Environmental Samples 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象