检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Antony Raj Gomes Pannala Raghuram J. Sriramulu Nimmakalaya Srinivas
机构地区:[1]不详
出 处:《American Journal of Analytical Chemistry》2011年第3期314-323,共10页美国分析化学(英文)
摘 要:This research article describes stability indicating fast liquid chromatographic method for determination of chromatographic purity and assay of Nizatidine as a alternate for two different methods for chromatographic purity and assay as given in USP Monograph and Ph.Eur Monograph. Proposed method is developed on Waters symmetry RP18 (50 × 4.6 mm), 3.5 μm stationary phase using gradient elution with combination of Ammonium acetate Diethyl amine buffer, Methanol and Tetrahydrofuran as mobile phase. Favorable results are obtained under developed conditions, which guarantee good separation of studied components. Whereas, data obtained from method validation confirm specificity, high sensitivity, linearity in a range of studied concentrations, repeatability and good accuracy of this method. Considerable degradation observed in oxidation stress condition was detected by this method. Eight impurities are studied among which impurity-5 is found major degradant. The stress samples are assayed against a qualified standard and the mass balance is found close to 99.2%. The developed method can be used for routine samples as well as stability studies.This research article describes stability indicating fast liquid chromatographic method for determination of chromatographic purity and assay of Nizatidine as a alternate for two different methods for chromatographic purity and assay as given in USP Monograph and Ph.Eur Monograph. Proposed method is developed on Waters symmetry RP18 (50 × 4.6 mm), 3.5 μm stationary phase using gradient elution with combination of Ammonium acetate Diethyl amine buffer, Methanol and Tetrahydrofuran as mobile phase. Favorable results are obtained under developed conditions, which guarantee good separation of studied components. Whereas, data obtained from method validation confirm specificity, high sensitivity, linearity in a range of studied concentrations, repeatability and good accuracy of this method. Considerable degradation observed in oxidation stress condition was detected by this method. Eight impurities are studied among which impurity-5 is found major degradant. The stress samples are assayed against a qualified standard and the mass balance is found close to 99.2%. The developed method can be used for routine samples as well as stability studies.
关 键 词:COLUMN Liquid CHROMATOGRAPHY NIZATIDINE FORCED Degradation Validation Stability Indicating
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145