Rapid Validated Stability Indicating Method for Nizatidine and Its Impurities Quantification  

Rapid Validated Stability Indicating Method for Nizatidine and Its Impurities Quantification

在线阅读下载全文

作  者:Antony Raj Gomes Pannala Raghuram J. Sriramulu Nimmakalaya Srinivas 

机构地区:[1]不详

出  处:《American Journal of Analytical Chemistry》2011年第3期314-323,共10页美国分析化学(英文)

摘  要:This research article describes stability indicating fast liquid chromatographic method for determination of chromatographic purity and assay of Nizatidine as a alternate for two different methods for chromatographic purity and assay as given in USP Monograph and Ph.Eur Monograph. Proposed method is developed on Waters symmetry RP18 (50 × 4.6 mm), 3.5 μm stationary phase using gradient elution with combination of Ammonium acetate Diethyl amine buffer, Methanol and Tetrahydrofuran as mobile phase. Favorable results are obtained under developed conditions, which guarantee good separation of studied components. Whereas, data obtained from method validation confirm specificity, high sensitivity, linearity in a range of studied concentrations, repeatability and good accuracy of this method. Considerable degradation observed in oxidation stress condition was detected by this method. Eight impurities are studied among which impurity-5 is found major degradant. The stress samples are assayed against a qualified standard and the mass balance is found close to 99.2%. The developed method can be used for routine samples as well as stability studies.This research article describes stability indicating fast liquid chromatographic method for determination of chromatographic purity and assay of Nizatidine as a alternate for two different methods for chromatographic purity and assay as given in USP Monograph and Ph.Eur Monograph. Proposed method is developed on Waters symmetry RP18 (50 × 4.6 mm), 3.5 μm stationary phase using gradient elution with combination of Ammonium acetate Diethyl amine buffer, Methanol and Tetrahydrofuran as mobile phase. Favorable results are obtained under developed conditions, which guarantee good separation of studied components. Whereas, data obtained from method validation confirm specificity, high sensitivity, linearity in a range of studied concentrations, repeatability and good accuracy of this method. Considerable degradation observed in oxidation stress condition was detected by this method. Eight impurities are studied among which impurity-5 is found major degradant. The stress samples are assayed against a qualified standard and the mass balance is found close to 99.2%. The developed method can be used for routine samples as well as stability studies.

关 键 词:COLUMN Liquid CHROMATOGRAPHY NIZATIDINE FORCED Degradation Validation Stability Indicating 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象