相关期刊:《CSEE Journal of Power and Energy Systems》《Protection and Control of Modern Power Systems》《Journal of Modern Power Systems and Clean Energy》《Energy Engineering》更多>>
supported by the National Natural Science Foundation of China(No.52377098)。
High-precision synchronized measurement data with short measurement latency are required for the applications of phasor measurement units(PMUs).This paper proposes a synchrophasor measurement method based on cascaded ...
supported by National Natural Science Foundation of China(No.52077004).
The subsynchronous oscillations(SSOs)related to renewable generation seriously affect the stability and safety of the power systems.To realize the dynamic monitoring of SSOs by utilizing the high computational efficie...
supported by the National Natural Science Foundation of China(U1766214,U2066601).
With integration of a larger amount of clean power sources and power electronic equipment,operation and dynamic characteristics of the power grid are becoming more and more complicated and stochastic.Therefore,it is n...
supported by Fundamental Research Funds for the Central Universities(No.2019RC006);National Natural Science Foundation of China(No.52077004)。
To completely eliminate the time delays caused by phasor data compressions for real-time synchrophasor applications,a real-time synchrophasor data compression(RSDC)is proposed in this paper.The two-way rotation charac...
supported by the China Key Technology Research on Risk Perception of Sub-Synchronous Oscillation of Grid with Large-Scale New Energy Access SGTYHT/21-JS-223.
In recent years,subsynchronous resonance(SSR)has frequently occurred in DFIG-connected series-compensated systems.For the analysis and prevention,it is of great importance to achieve wide area monitoring of the incide...
supported by the National Natural Science Foundation of China(No.51725702)。
Laboratory testing of phasor measurement units(PMUs)guarantees their performance under laboratory conditions.However,many factors may cause PMU measurement problems in actual power systems,resulting in the malfunction...
This work was supported by SGCC Science and Technology Program under project“AI-based oscillation detection and control”(SGJS0000DKJS1801231)。
Due to its high accuracy and ease of calculation,synchrophasor-based linear state estimation(LSE)has attracted a lot of attention in the last decade and has formed the cornerstone of many wide area monitor system(WAMS...
Introduction:Aspects of power system protection which contributes to mal-operations and blackouts can be improved by supervision of system behavior and response based analysis rather than condition-based or event-base...
supported by the National Science Foundation of China (No.CNS-1553494);the Department of Energy Grant (No. 800006104)
Synchrophasor devices guarantee situation awareness for real-time monitoring and operational visibility of smart grid. With their widespread implementation,significant challenges have emerged, especially in communicat...
Synchrophasors are time-synchronized electrical measurements that represent both the magnitude and phase angle of the electrical sinusoids. Synchrophasors are measured by fast time-stamped devices called phasor measur...