Progresses on SAR Remote Sensing of Tropical Forests:Forest Biomass Retrieval and Analysis of Changing Weather Conditions被引量:2
《Journal of Geodesy and Geoinformation Science》2021年第1期88-93,共6页Stefano TEBALDINI Xinwei YANG Yu BAI Mauro Mariotti D’ALESSANDRO Mingsheng LIAO Wen YANG 
This paper is intended to report on the progresses made during the Dragon-4 project Three and Four-Dimensional Topographic Measurement and Validation(ID:32278),sub-project Multi-baseline SAR Processing for 3 D/4 D Rec...
关键词:tropical forest BIOMASS SAR tomography Li DAR temporal decorrelation 
ID-OCTA:OCT angiography based on inverse SNR and decorrelation features被引量:10
《Journal of Innovative Optical Health Sciences》2021年第1期3-17,共15页Huakun Li Kaiyuan Liu Lin Yao Xiaofeng Deng Ziyi Zhang Peng Li 
The authors are thankful to National Natural Science Foundation of China(62075189);Zhejiang Provincial Natural Science Foundation of China(LR19F050002);Zhejiang Lab(2018EBOZX01);Fundamental Research Funds for the Central Universities(2018FZA5003).
Optical coherence tomography angiography(OCTA)takes the flowing red blood cells(RBCs)as intrinsic contrast agents,enabling fast and three-dimensional visualization of vasculature per-fusion down to capillary level,wit...
关键词:Medical and biological imaging optical coherence tomography angiography(OCTA) motion-contrast multi-features classifier OCTA quantification 
Several Kinematic Data Processing Methods for Time-Correlated Observations被引量:5
《Journal of Geodesy and Geoinformation Science》2019年第4期1-9,共9页Bofeng LI Zhetao ZHANG 
The National Natural Science Foundation of China(Nos.41574031;41622401);The Scientific and Technological Innovation Plan from Shanghai Science and Technology Committee(Nos.17511109501;17DZ1100802;17DZ1100902);The Fundamental Research Funds for the Central Universities(No.2019B03714)。
Time correlations always exist in modern geodetic data,and ignoring these time correlations will affect the precision and reliability of solutions.In this paper,several methods for processing kinematic time-correlated...
关键词:time correlation kinematic solution decorrelation transformation differential transformation maximum a posteriori estimation 
Seeing through dynamics scattering media:Suppressing diffused reflection based on decorrelation time difference
《Journal of Innovative Optical Health Sciences》2019年第4期67-73,共7页Honglin Liu Xin Wang Jingjing Gao Tingyi Yu Shensheng Han 
We observed a phenomenon that different scattering components have different decorrelation time.Based on decorrelation time difference,we proposed a method to image an object hidden behind a turbid medium in a reflect...
关键词:Keyuords:Decorrelation time dynamic scattering media speckle atorrelation menory efect reflection mode 
Application of InSAR in Surface Deformation Monitoring of Electric Power Line Selection
《Journal of Computer and Communications》2019年第7期39-52,共14页Qiang Liu Tianyong Chu Yumin Tan Wuttichai Boonpook 
In the process of site selection and the facility construction in power engineering, the geological conditions of the foundation have an important impact on the displacement of completed power facilities. Usually, the...
关键词:Power Line Sentinel-1Adata Volume Scattering DECORRELATION LONG-TIME BASELINE 
Vessel density and En-face segmentation of optical coherence tomography angiography to analyse corneal vascularisation in an animal model被引量:1
《Eye and Vision》2019年第1期6-16,共11页Kavya Devarajan Wen Di Lee Hon Shing Ong Nyein C.Lwin Jacqueline Chua Leopold Schmetterer Jodhbir S.Mehta Marcus Ang 
Background:Optical coherence tomography angiography(OCTA)is a novel non-invasive angiography technology that has recently been extensively studied for its utility in anterior segment imaging.In this study,we compared ...
关键词:OCTA Corneal vascularisation Optical micro angiography Split-spectrum amplitude decorrelation angiography Vessel density Anterior segment En-face OCTA 
Sequential nonlinear tracking filter without requirement of measurement decorrelation
《Journal of Systems Engineering and Electronics》2015年第6期1135-1141,共7页Gongjian Zhou Junhao Xie Rongqing Xu Taifan Quan 
supported by the National Natural Science Foundation of China(61201311;61132005);the Aerospace Science Foundation of China(20142077010)
Sequential measurement processing is of benefit to both estimation accuracy and computational efficiency. When the noises are correlated across the measurement components, decorrelation based on covariance matrix fact...
关键词:sequential filter Doppler measurement measurementdecorrelation minimum mean squared error (MMSE). 
Transmission efficiency improvement of the injector line of SFC by particle beam decorrelation
《Nuclear Science and Techniques》2015年第6期29-34,共6页杨尧 原有进 冯玉成 孙良亭 方兴 卢旺 张文慧 曹云 张雪珍 赵红卫 
Supported by the National Basic Research Program of China(No.2014CB845500);the 100 Talents Program of the CAS(No.Y214160BR0);National Nature Science Foundation of China(No.11221064)
The operation of the HIRFL accelerator has shown that the beam transmission efficiency of the sector focusing cyclotron(SFC) injector line is rather poor. Beam simulations have been performed to investigate the possib...
关键词:束流传输效率 喷油器 线路 粒子束 HIRFL加速器 电子回旋共振 光束质量 运行方案 
Temporal decorrelation model for the bistatic SAR interferometry
《Journal of Systems Engineering and Electronics》2015年第1期77-84,共8页Qilei Zhang Wenge Chang 
supported by the National Natural Science Foundation of China(61101178;61271441)
This paper develops a temporal decorrelation model for the bistatic synthetic aperture radar(BSAR) interferometry. The temporal baseline is one of the important decorrelation sources for the repeat-pass synthetic ap...
关键词:temporal decorrelation bistatic synthetic aperture radar(BSAR) INTERFEROMETRY geometry configuration 
KEY TECHNOLOGY OF D-INSAR AT X-BAND FOR MONITORING LAND SUBSIDENCE IN MINING AREA AND ITS APPLICATION被引量:5
《Journal of Electronics(China)》2014年第5期441-452,共12页Li Xinglin Liu Donglie Song Hongjun Chen Runpu Li Hongyu 
In theory, land subsidence measurement results with high accuracy can be obtained by using the Differential Interferometry Synthetic Aperture Radar(D-InSAR) at X-band. In practice, however, the measuring accuracy of D...
关键词:Differential Interferometry Synthetic subsidence monitoring DECORRELATION Atmospheric Aperture Radar (D-InSAR) Mining area Land effects High deformation gradient 