Before rise-to-power tests, the actual measured value of heat released from the Reactor Pressure Vessel(RPV) or removed by the Vessel Cooling System(VCS) cannot be obtained. It is difficult for operators to evaluate t...
An attempt is made to investigate the ability of the revised K FIX code to the solution to natural convection. The new experimental data of the benchmark problem of the IAEA coordinated research program (CRP 3) on hea...