机构地区:[1]Department of Radiotherapy, Institut de Cancérologie de la Loire [2]Department of Radiation Oncology, Institut Gustave Roussy, Université Paris XI [3]Department of Radiation Oncology, Hpital d'Instruction des Armées du Val-de-Grace [4]Department of Internal Medicine, CHU Saint Etienne
出 处:《World Journal of Radiology》2013年第4期173-177,共5页世界放射学杂志(英文版)(电子版)
摘 要:AIM:To assess the feasibility of volumetric intensity-modulated arc radiotherapy (VMAT) in patients with limited polyneuropathy, organomegaly, endocrinopathy, monoclonal gammopathy, and skin changes syndrome. METHODS:A 70-year-old male with histologically confirmed osteosclerotic myeloma was treated in our department in July 2010 with VMAT. Fourty-six Gray in 23 fractions were given on three bone lesions. Doses delivered to target volume and critical organs were compared with a tridimensional conformal radiotherapy (3D-RT) plan. Treatment was well tolerated without any side effects.RESULTS:VMAT improved dose homogeneity within the target volume, as compared to 3D-RT (standard deviations:2.9 Gy and 1.6 Gy for 3D and VMAT, respectively). VMAT resulted in a better sparing of critical organs. Dose delivered to 20% of organ volume (D20) was reduced from 22 Gy (3D-RT) to 15 Gy (VMAT) for small bowel, from 24 Gy (3D-RT) to 17 Gy (VMAT) for bladder and from 47 Gy (3D-RT) to 3 Gy (VMAT) for spinal cord. Volumes of critical organs that received at least 20 Gy (V20) were decreased by the use of VMAT, as compared to 3D-RT (V20 bladder:10% vs 99%; V20 small bowel:6% vs 21%). One year after treatment completion, no tumor progression has been reported. CONCLUSION:VMAT improved dose distribution as compared to 3D-RT for limited osteosclerotic myeloma, with better saving of critical organs.AIM:To assess the feasibility of volumetric intensity-modulated arc radiotherapy (VMAT) in patients with limited polyneuropathy, organomegaly, endocrinopathy, monoclonal gammopathy, and skin changes syndrome. METHODS:A 70-year-old male with histologically confirmed osteosclerotic myeloma was treated in our department in July 2010 with VMAT. Fourty-six Gray in 23 fractions were given on three bone lesions. Doses delivered to target volume and critical organs were compared with a tridimensional conformal radiotherapy (3D-RT) plan. Treatment was well tolerated without any side effects.RESULTS:VMAT improved dose homogeneity within the target volume, as compared to 3D-RT (standard deviations:2.9 Gy and 1.6 Gy for 3D and VMAT, respectively). VMAT resulted in a better sparing of critical organs. Dose delivered to 20% of organ volume (D20) was reduced from 22 Gy (3D-RT) to 15 Gy (VMAT) for small bowel, from 24 Gy (3D-RT) to 17 Gy (VMAT) for bladder and from 47 Gy (3D-RT) to 3 Gy (VMAT) for spinal cord. Volumes of critical organs that received at least 20 Gy (V20) were decreased by the use of VMAT, as compared to 3D-RT (V20 bladder:10% vs 99%; V20 small bowel:6% vs 21%). One year after treatment completion, no tumor progression has been reported. CONCLUSION:VMAT improved dose distribution as compared to 3D-RT for limited osteosclerotic myeloma, with better saving of critical organs.
关 键 词:VOLUMETRIC intensity-modulated ARC RADIOTHERAPY Conformal RADIOTHERAPY Critical organs Osteosclerotic MYELOMA Polyneuropathy organomegaly ENDOCRINOPATHY monoclonal GAMMOPATHY and skin change syndrome
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...