External sclerostomy with the femtosecond laser versus a surgical knife in rabbits  被引量:1

External sclerostomy with the femtosecond laser versus a surgical knife in rabbits

在线阅读下载全文

作  者:Yao Shi, Fa-Gang Jiang 

机构地区:[1]Department of Pediatrics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, Hubei Province, China [2]Department of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, Hubei Province, China [3]Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, Hubei Province, China

出  处:《International Journal of Ophthalmology(English edition)》2012年第3期258-265,共8页国际眼科杂志(英文版)

基  金:National Natural Science Foundation ofChina (No.30772382 and No.81100701);the FundamentalResearch Funds for the Central Universities of China (No.2011JC044)

摘  要:AIM: To experimentally compare the external sclerostomy produced using a femtosecond laser with that made by a surgical knife and to evaluate the healing patterns, efficacy and technical advantages of femtosecond laser sclerostomy. METHODS: In a prospective randomized, controlled, masked-observer study, 10 pigmented rabbits underwent external sclerostomy with a femtosecond laser in the right eye; 10 additional rabbits underwent sclerostomy with a surgical superblade in the right eye. Clinical characteristics, which included bleb morphology and intraocular pressure, were recorded for 1 month after surgery. Six additional rabbits underwent external femtosecond laser sclerostomy in the right eye and mechanical sclerostomy in the left eye and were killed at day 14 after surgery. Histologic staining, immunohistochemistry and scanning electron microscopy were subsequently performed to assess the morphology of the filtering fistula. The titanium-sapphire femtosecond laboratory laser was operating at a repetition rate of 1 kHz, 0.4 mJ pulse energy, a central wavelength of 800nm and a pulse duration of 50 femtoseconds. Mann-Whitney and Kaplan-Meier tests were used for statistical analysis. RESULTS: Successful complete sclerostomy was achieved in each laser-treated eye which was hit only once by the laser. The laser treated time was approximately 15s-16s. In the laser-treated group (n =16), 2 eyes (12%) developed mild hyphema at the site of entry and 8 eyes (50%) showed transient edema in the corneal periphery adjacent to the laser impact zone. The differences between the groups in duration of function blebs and pressure reduction were statistically significant (P=0.025 and 0.016, respectively). The success rate of the laser-treated group was significantly higher than the knife group (P=0.005). Histologically, the subconjunctival connective tissue was loosely arranged with partially patent sclerostomy in the laser-treated eyes at postoperative day 14. This contrasted with the completely scarred sclerostomy tract in the kniAIM: To experimentally compare the external sclerostomy produced using a femtosecond laser with that made by a surgical knife and to evaluate the healing patterns, efficacy and technical advantages of femtosecond laser sclerostomy. METHODS: In a prospective randomized, controlled, masked-observer study, 10 pigmented rabbits underwent external sclerostomy with a femtosecond laser in the right eye; 10 additional rabbits underwent sclerostomy with a surgical superblade in the right eye. Clinical characteristics, which included bleb morphology and intraocular pressure, were recorded for 1 month after surgery. Six additional rabbits underwent external femtosecond laser sclerostomy in the right eye and mechanical sclerostomy in the left eye and were killed at day 14 after surgery. Histologic staining, immunohistochemistry and scanning electron microscopy were subsequently performed to assess the morphology of the filtering fistula. The titanium-sapphire femtosecond laboratory laser was operating at a repetition rate of 1 kHz, 0.4 mJ pulse energy, a central wavelength of 800nm and a pulse duration of 50 femtoseconds. Mann-Whitney and Kaplan-Meier tests were used for statistical analysis. RESULTS: Successful complete sclerostomy was achieved in each laser-treated eye which was hit only once by the laser. The laser treated time was approximately 15s-16s. In the laser-treated group (n =16), 2 eyes (12%) developed mild hyphema at the site of entry and 8 eyes (50%) showed transient edema in the corneal periphery adjacent to the laser impact zone. The differences between the groups in duration of function blebs and pressure reduction were statistically significant (P=0.025 and 0.016, respectively). The success rate of the laser-treated group was significantly higher than the knife group (P=0.005). Histologically, the subconjunctival connective tissue was loosely arranged with partially patent sclerostomy in the laser-treated eyes at postoperative day 14. This contrasted with the completely scarred sclerostomy tract in the kni

关 键 词:femtosecond laser SCLEROSTOMY FIBROSIS GLAUCOMA 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象