检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]华东理工大学生化工程研究所,上海200237
出 处:《分析化学》1993年第12期1449-1451,共3页Chinese Journal of Analytical Chemistry
摘 要:利用铂化电极的大表面吸附葡萄糖氧化酶(简称GOD)构建了一种具有良好操作性能的微酶电极,在0~10mmol/L葡萄糖浓度具有很好线性,相关系数γ=0.9998,响应时间短(<20s),精度高。利用该电极组成三电极流动注射分析系统,这种系统同样有较好的线性范围,分析频率达45h^(-1),使用寿命在一周以上。Micro-enzyme electrode was fabricated on a mioro-platinum electrode surface by taking advantage of very huge surface of platinized platinum. The micro-enzyme electrode for glucose showed high performance: good linearity (for glucose concentration of 0-10 mmol/L),fast response (100% response 20 s) and accuracy. A flow injection analysis system incorporating the micro-enzyme electrode was described. It also exhibited good performance. The life time for normal use during the flow injection analysis of glucose was one week at room temperature. The system may serve for on-line monitoring of glucose in fermentattion processes.
分 类 号:TQ920.1[轻工技术与工程—发酵工程]