氢化物发生-原子荧光光谱法测定大米中微量硒  被引量:1

HG-AFS determination of trace amounts of selenium in rice

在线阅读下载全文

作  者:兰建丽[1] 徐凤云[1] 兰建敏 

机构地区:[1]完达山乳业股份有限公司,黑龙江哈尔滨150078

出  处:《粮油食品科技》2005年第3期43-44,共2页Science and Technology of Cereals,Oils and Foods

摘  要:研究了氢化物-原子荧光光谱法对大米中微量硒的测定,方法灵敏度高、准确度好。在最佳条件下,荧光强度与硒浓度在0.213~100ng/mL范围内呈线性关系,检出限达0.213ng/mL,相对标准偏差为2.2%以下,回收率为99.13%~105.20%。The optimum conditions for the HG-AFS determination of selenium were studied and an AFS method for the determination of selenium in rice is proposed.High sensibility and fine accuracy were shown in this method.Under the conditions proposed,the fluorescence intensity and selenium concentration were in a linear relationship within the limits of 0.213~100ng/mL.Selenium detection limit is found to be 0.213ng/mL and the RSD were under 2.2%.The selenium recovery was 99.13%~105.20%.

关 键 词:氢化物发生-原子荧光光谱法 测定 大米  

分 类 号:TS207.3[轻工技术与工程—食品科学]

 