检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王永鑫[1] 马斌[1] 张万江[1] 韩中华[1] 阎焕忠[1]
机构地区:[1]沈阳建筑大学信息与控制学院,辽宁沈阳110168
出 处:《现代建筑电气》2010年第1期4-8,共5页Modern Architecture Electric
基 金:国家科技支撑计划子课题(2008BA08B08-05)
摘 要:通过对常规PID控制的分析,结合模糊理论、串级控制理论和专家经验,提出了动态自动整定PID控制系统中3个参数,使系统达到最佳工作状态的方法,从而使系统供水温度恒定。最终试验结果表明,将模糊自整定PID控制系统应用于集中供热时,即使室外温度发生变化,系统也可迅速作出反应,将输出温度稳定在用户所需的舒适度范围内,并且具有较强的抗干扰能力。Through the analysis of conventional PID control, combined with the fuzzy theory, cascade control theory and experience of experts, the three parameters' method of a dynamic auto-tuning PID control system was put forward which allowed the system to achieve the best working state of the methods to the system water temperature constant. The system final test results showed that when the fuzzy self-tuning PID control system was used in central heating even the outdoor temperature changed, it also could respond quickly to temperature-stable output required for comfort in the user context, and had strong anti-jamming capability.
分 类 号:TP273.4[自动化与计算机技术—检测技术与自动化装置]