检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]大连依利特分析仪器有限公司,辽宁大连116023 [2]辽宁大连依利特分析仪器工程技术研究中心,辽宁大连116023
出 处:《现代科学仪器》2012年第1期98-100,共3页Modern Scientific Instruments
摘 要:通过自构建的微柱液相色谱系统上色谱条件的优化,建立了一种同时检测食品中苯甲酸和山梨酸的新方法。食品中苯甲酸和山梨酸经提取后,6分钟内达到基线分离,与常规高效液相色谱法相比,分析时间缩短,流动相消耗减少。在1~25 mg/L浓度范围内线性关系良好,相关系数分别为0.9999和0.9997。苯甲酸和山梨酸的回收率均在94.7%~103.1%之间,三次平行加标回收率测试,相对标准偏差分别为1.12%和1.29%。该方法稳定性好,回收率高,能快速、准确的检测食品中苯甲酸和山梨酸。A new method of analysis of benzoic acid and sorbic acid in foodstuff was developed by condition optimization based on the self-constructed micro-column liquid chromatography system.Benzoic acid and sorbic acid were completely separated from each other in 6 minutes.Compared with traditional HPLC,an obvious reduction of analytical time and mobile phase was obtained.Good linear correlations was available between the peak areas and concentration ranging from 1mg/L to 25mg/L,and the correlation coefficient are 0.9999 and 0.9997,respectively.The recoveries of benzoic acid and sorbic acid were in 94.7~ 103.1%,and the relative standard deviation were 1.12% and 1.29%,respectively.This method can be applied to the determination of the benzoic acid and sorbic acid in foodstuff with good results.
分 类 号:TS207.3[轻工技术与工程—食品科学] O657.72[轻工技术与工程—食品科学与工程]