检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国疾病预防控制中心营养与食品安全所,北京100021
出 处:《卫生研究》2012年第3期462-466,共5页Journal of Hygiene Research
摘 要:目的建立适用于面制食品中铝含量的分光光度检测方法。方法样品经微波消解法或湿消解法消解后,用分光光度法测定食品中铝的含量。结果铝浓度在0.25~5.0μg/ml范围内呈现良好的线性关系,相关系数r=0.9998。检出限(LOD)为:2.3ng/ml;定量限(LOQ)为:7ng/ml。结论该方法用于面制食品中铝含量的测定,方法简便、快速,结果准确可靠。Objective To establish a determination method for aluminium in flour foods with photometric method. Methods After samples being treated with microwave digestion and wet digestion, aluminium in staple flour foods was determined by photometric method. Results There was a good linearity of the result in the range of 0.25 -5.0μg/ml aluminium, r = 0. 9998 ; limit of detection(LOD) :2. 3ng/ml; limit of quantitation(LOQ) :7ng/ml. Conclusion This method of determining aluminium in flour foods is simple, rapid and reliable.
分 类 号:R155.5[医药卫生—营养与食品卫生学] TS207.3[医药卫生—公共卫生与预防医学]