检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:GONG Wei DOU Zhi-yu CUI Li-li LIU Da-jun HE Xing-quan
出 处:《Chemical Research in Chinese Universities》2012年第6期1047-1053,共7页高等学校化学研究(英文版)
基 金:Supported by the Natural Science Foundation of Jilin Province,China(No.20090326)
摘 要:A novel covalently modified glassy carbon electrode with β-cyclodextrin was prepared via electropolymerization technique for the simultaneous determination of uric acid(UA),xanthine(XA),hypoxanthine(HX) and dopamine(DA).This new electrode presented an excellent electrocatalytic activity towards the oxidation of UA,XA,HX and DA by cyclic voltammetry(CV) method.The oxidation peaks of the four compounds were well defined and had the enhanced peak currents.The separation potentials of the oxidation peaks for DA-UA,UA-XA and XA-HX were 150,390 and 360 mV in CV,respectively.By means of differential pulse voltammetry(DPV) method,the calibration curves in the ranges of 10―225,5―105,10―170 and 5―150 μmol/L were obtained for UA,XA,HX and DA,respectively.The lowest detection limits(S/N=3) were 5,1.25,5 and 1.5 μmol/L for UA,XA,HX and DA,respectively.The practical application of the modified electrode was demonstrated by the determination of DA in hydrochloride injection and UA,XA,HX in human urine samples.A novel covalently modified glassy carbon electrode with β-cyclodextrin was prepared via electropolymerization technique for the simultaneous determination of uric acid(UA),xanthine(XA),hypoxanthine(HX) and dopamine(DA).This new electrode presented an excellent electrocatalytic activity towards the oxidation of UA,XA,HX and DA by cyclic voltammetry(CV) method.The oxidation peaks of the four compounds were well defined and had the enhanced peak currents.The separation potentials of the oxidation peaks for DA-UA,UA-XA and XA-HX were 150,390 and 360 mV in CV,respectively.By means of differential pulse voltammetry(DPV) method,the calibration curves in the ranges of 10―225,5―105,10―170 and 5―150 μmol/L were obtained for UA,XA,HX and DA,respectively.The lowest detection limits(S/N=3) were 5,1.25,5 and 1.5 μmol/L for UA,XA,HX and DA,respectively.The practical application of the modified electrode was demonstrated by the determination of DA in hydrochloride injection and UA,XA,HX in human urine samples.
关 键 词:Β-CYCLODEXTRIN Uric acid XANTHINE HYPOXANTHINE DOPAMINE
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.128.172.178