检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:栗景蕊[1] 曹春然[1] 孙圆媛[1] 胡宇驰[1]
机构地区:[1]北京市药品检验所中药成分分析与生物评价北京市重点实验室,北京102206
出 处:《中国新药杂志》2017年第24期2989-2994,共6页Chinese Journal of New Drugs
摘 要:目的:对SAR107375E注射液细菌内毒素检查的可行性进行验证,建立合理的安全性检查方法。方法:将SAR107375E注射液进行细菌内毒素凝胶法检查,并通过干扰实验考察细菌内毒素凝胶法检查的适用性。在不适宜采用凝胶检查法的情况下,考虑建立家兔法进行热原检查。结果:SAR107375E注射液不适宜用细菌内毒素检查法进行质量控制,建立家兔热原检查法。结论:拟采用热原检查法对SAR107375E注射液进行质量控制。Objective:To verify the feasibility of bacterial endotoxin test for SAR107375E injection, and to establish a reasonable safety test method for the drug. Methods: SAR107375E injection were tested by bacterial endotoxin method(gel method), and the rationality was investigated by interference test. If it is not suitable for tested by bacterial endotoxin method(gel method) , then establish the rabbit method for pyrogen test. Results:As SAR107375E injection's quality, it is not suitable for controlled by bacterial endotoxin method( gel method) , it is necessary to establish a rabbit method for the pyrogen test. Conclusion: The quality of SAR107375E injection should be controlled by pyrogen test.
关 键 词:SAR107375E注射液 细菌内毒素检查 热原检查
正在载入数据...