摘  要:对用氢氧化钠标准溶液滴定黄酒中氨基酸态氮测定结果的不确定度进行了评定,对不确定度的来源进行分析和量化。影响黄酒中氨基酸态氮测定结果的主要原因是试样的取样量、试样的重复性测定、氢氧化钠标准溶液的配制、消耗氢氧化钠标准溶液的体积以及酸度计示值指示误差。检测黄酒试样中氨基酸态氮测定结果的扩展不确定度为0.03 g/L。The uncertainties in the measurement of amino acid nitrogen content in yellow rice wine by titration with sodium hydrox- ide standard solution were investigated. The source of the uncertainties was analyzed and quantified. The main factors influencing the measurement included sampling amount, repeated measurement, preparation of sodium hydroxide standard solution, the consumed volume of sodium hydroxide standard solution, and the error of acidity indicator. The extended uncertainty in the measurement of ami- no acid nitrogen in yellow rice wine samples was 0.03 g/L.