半微量定氮法中三氯乙酸提取挥发性盐基氮的改进  被引量:1

Improvement on extraction of volatile basic nitrogen by trichloroacetic acid in semimicro-kjeldahl determination method

在线阅读下载全文

作  者:黄忠意 周兴旺 马东兴 徐文泱 HUANG Zhong-Yi;ZHOU Xing-Wang;MA Dong-Xing;XU Wen-Yang(Hunan Institute of Food Quality Supervision Inspection and Research,Changsha 410007,China;Key Laboratory of Food Safety Monitoring and Early Warning of Hunan Province,Changsha 410007,China;Linyi Inspection and Testing Center,Linyi 276000,China)

机构地区:[1]湖南省食品质量监督检验研究院,长沙410007 [2]食品安全监测与预警湖南省重点实验室,长沙410007 [3]临沂市检验检测中心,临沂276000

出  处:《食品安全质量检测学报》2021年第12期4759-4763,共5页Journal of Food Safety and Quality

摘  要:目的改进半微量定氮法中三氯乙酸提取挥发性盐基氮的条件。方法比较了提取剂三氯乙酸和水的提取效果,并优化了三氯乙酸作提取剂时氧化镁的添加量,同时添加氯化铵做回收率实验。结果按照标准方法用三氯乙酸浸泡的样品检测结果明显偏低,其样品溶液碱度未能达到方法要求,经调整氧化镁添加量后,加标回收率为94.0%~95.6%,相对标准偏差(relative standard deviation, RSD)为0.57%;用水作提取剂的样品结果偏高,浸泡30 min过程中, pH值中性环境样品持续腐败。结论优化后的检验方法满足实验要求,且三氯乙酸给样品提供足够的酸性环境,抑制样品进一步腐败。Objective To improve the extraction conditions of volatile basic nitrogen by trichloroacetic acid in semimicro-kjeldahl determination method. Methods The extraction effect of trichloroacetic acid and water was compared. The addition amount of magnesium oxide when trichloroacetic acid was used as extraction agent were optimized. At the same time, ammonium chloride was added for recovery experiment. Results The test result of samples soaked with trichloroacetic acid according to the standard method was obviously low. The alkalinity of sample solution failed to meet the method requirements. After adjusting the supplemental amount of magnesium oxide, the recoveries rate of spiked sample by the optimized method were 94.0%-95.6%, and the relative standard deviations(RSDs) were 0.57%. The result of the sample with water as the extractant was high, and the sample in the pH-neutral environment continued to rot after being immersed for 30 min. Conclusion The optimized test method meets the experimental requirements, and trichloroacetic acid provides sufficient acidic environment for the samples to inhibit further spoilage changes.

关 键 词:三氯乙酸 氧化镁 挥发性盐基氮 半微量定氮法 

分 类 号:TS207.3[轻工技术与工程—食品科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象