石墨炉原子吸收光谱法测定特医食品中钼含量  被引量:4

Determination of Molybdenum in Formula Food for Special Medical Use by Graphite Furnace Atomic Absorption Spectrometry

在线阅读下载全文

作  者:李清清[1] 严睿 宋瑞[1] 彭亚峰[1] LI Qingqing;YAN Rui;SONG Rui;PENG Yafeng(Shanghai Institute of Quality Inspection and Technical Research/National Food Quality Supervision and Inspection Center,Shanghai 200233)

机构地区:[1]上海市质量监督检验技术研究院,国家食品质量监督检验中心(上海),上海200233

出  处:《食品工业》2021年第9期308-311,共4页The Food Industry

摘  要:试验旨在建立石墨炉原子吸收光谱测定特殊医学用途配方食品中钼含量的分析方法。考察微波、湿法、干法3种消解方式对方法的适用性,探讨仪器升温程序、基体改进剂等关键检测条件,并对方法进行方法学验证。结果表明,钼元素在5~40μg/L范围内线性关系良好,方法定量限为0.05 mg/kg,在0.05, 0.10和0.20 mg/kg这3个加标水平下,回收率为95.6%~98.0%, 7次重复测定精密度为3.34%。该试验方法操作简便,灵敏度和精密度均满足特殊医学用途配方食品中钼含量的分析需求。A method of graphite furnace atomic absorption spectrometry was established for the determination of molybdenum in formula food for special medical use.The applicability of microwave digestion,wet digestion and dry digestion to the method were investigated.The pre-treatment condition,instrument heating program,matrix improver and other detection conditions were discussed,and the method was verified by methodological verification.The results showed that the linear relationship of the molybdenum was good in the range of 5-40 μg/L,and the detection limit was 0.05 mg/kg.At the three spiked levels of 0.05,0.10 and 0.20 mg/kg,the recovery was between 95.6% and 98.0%.The precision of 7 repeated determinations was 3.34%.The method is simple to operate,and the sensitivity and precision can meet the requirement of molybdenum content analysis in formula food for special medical use.

关 键 词:特殊医学用途配方食品  原子吸收光谱法 

分 类 号:O657.31[理学—分析化学] TS218[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象