An Application of Gas Chromatography-Mass Spectrometry (GC-MS) Fast Automated Scan/SIM Type (FASST) in Determining the Preservative Levels in Foods  被引量:2

An Application of Gas Chromatography-Mass Spectrometry (GC-MS) Fast Automated Scan/SIM Type (FASST) in Determining the Preservative Levels in Foods

在线阅读下载全文

作  者:Eman Wajeh Ammen Raghad Al-Salhi 

机构地区:[1]Department of Chemistry, College of Science, University of Al-Mustansiriyah, Baghdad, Iraq [2]Directorate of Materials Research, Ministry of Science and Technology, Baghdad, Iraq

出  处:《American Journal of Analytical Chemistry》2017年第5期307-316,共10页美国分析化学(英文)

摘  要:The preservatives used in food products are strictly monitored and regulated. The present study aims to imply a sensitive and reliable analytical method to quantify two classes of preservatives (i.e. carboxylic acid and phenolic compounds) in food by means of gas chromatography-mass spectrometry (GC-MS), aimed at monitoring the products available within the local stores. Target analytes were derivatized via aqueous-phase isobutyl chloroformate-mediated reaction followed by dispersive liquid-liquid microextraction (DLLME) method. The quantity and quality determination of the studied samples were assured by performing FASST approach in a single run GC-MS analysis. The combination of standard addition method with sample dilution compensated the effect of sample matrix on the quantitative determination of the tested preservatives in the examined samples. The concentrations of sorbic acid (SA) were 210 μg/mL and 1000 μg/mL in soft drink and sauces samples, respectively. On the other hand, sodium benzoate (226 μg/mL) was only found in soft drink, whereas, no parabens were detected in any samples collected from the local stores.The preservatives used in food products are strictly monitored and regulated. The present study aims to imply a sensitive and reliable analytical method to quantify two classes of preservatives (i.e. carboxylic acid and phenolic compounds) in food by means of gas chromatography-mass spectrometry (GC-MS), aimed at monitoring the products available within the local stores. Target analytes were derivatized via aqueous-phase isobutyl chloroformate-mediated reaction followed by dispersive liquid-liquid microextraction (DLLME) method. The quantity and quality determination of the studied samples were assured by performing FASST approach in a single run GC-MS analysis. The combination of standard addition method with sample dilution compensated the effect of sample matrix on the quantitative determination of the tested preservatives in the examined samples. The concentrations of sorbic acid (SA) were 210 μg/mL and 1000 μg/mL in soft drink and sauces samples, respectively. On the other hand, sodium benzoate (226 μg/mL) was only found in soft drink, whereas, no parabens were detected in any samples collected from the local stores.

关 键 词:Food PRESERVATIVES GC-MS FASST Acquisition CHLOROFORMATE DERIVATIZATION DLLME 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象