检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Shashikant B. Landge Sunil B. Dahale Sanjay A. Jadhav Pavankumar V. Solanki Saroj R. Bembalkar Vijayavitthal T. Mathad
机构地区:[1]Department of Process Research and Development, Megafine Pharma (P) Ltd., Maharashtra, India [2]Department of Chemistry, Deogiri College, Aurangabad, India
出 处:《American Journal of Analytical Chemistry》2017年第6期380-394,共15页美国分析化学(英文)
摘 要:A new, specific, rapid and stability indicating reversed phase liquid chro-matographic (RP-LC) method for the determination of process related and degradation related impurities of Apremilast has been developed and validated. The degradation study performed in acid, base, oxidative, photolytic, and thermal stressed conditions. Eight process related impurities (Imp-1 to Imp-8) in test sample of Apremilast have been detected by developed RP-LC method. The good chromatographic resolution between the peaks of process related impurities, degradation impurities and Apremilast has been achieved on a Synergi Max-RP 80 A (150 × 4.6 mm ID), 4 μ column. The process and degradation related impurities were characterized by mass spectrometry, 1H NMR and FT-IR spectral data. The method was validated as per ICH guideline and found to be specific, rapid, and stability indicating. The proposed RP-PLC method was successfully applied to the analysis of drug substance samples of Apremilast.A new, specific, rapid and stability indicating reversed phase liquid chro-matographic (RP-LC) method for the determination of process related and degradation related impurities of Apremilast has been developed and validated. The degradation study performed in acid, base, oxidative, photolytic, and thermal stressed conditions. Eight process related impurities (Imp-1 to Imp-8) in test sample of Apremilast have been detected by developed RP-LC method. The good chromatographic resolution between the peaks of process related impurities, degradation impurities and Apremilast has been achieved on a Synergi Max-RP 80 A (150 × 4.6 mm ID), 4 μ column. The process and degradation related impurities were characterized by mass spectrometry, 1H NMR and FT-IR spectral data. The method was validated as per ICH guideline and found to be specific, rapid, and stability indicating. The proposed RP-PLC method was successfully applied to the analysis of drug substance samples of Apremilast.
关 键 词:Apremilast Stability Indicating RP-LC PDE4 INHIBITOR FORCED DEGRADATION
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.144.156.43