supported by the National Key Research and Development Program (No.2022YFC2407001)。
OBJECTIVE To evalu ate the role of resting magnetocardiography in identifying seve re coronary artery stenosis in patients with suspected coronary artery disease.METHODS A total of 513 patients with angina symptoms we...
supported by the Suzhou Tsinghua innovation leading action project(Grant No.2016SZ0217);the National Key Research and Development Program of China(Grant No.2016YFB0500902)。
Several critical clinical applications of magnetocardiography(MCG)involve its T wave.The T wave’s accuracy directly affects the diagnostic accuracy of MCG for ischemic heart disease and arrhythmogenic.Tunnel magnetor...
the Open Research Fund of Anhui Key Laboratory of Detection Technology and Energy Saving Devices,Anhui Polytechnic University(Grant No.JCKJ2021A03);the Introduced Talent Research Startup Funds of Anhui Polytechnic University(Grant Nos.2021YQQ006 and 2020YQQ040);the National Natural Science Foundation of China(Grant No.62101004)。
For a magnetocardiography(MCG)system inside a magnetically shielded room(MSR),the residual field should be further suppressed to obtain high-quality MCG signals.In this paper,a compensation system has been developed b...
Project supported by the National Natural Science Foundation of China(Grant No.61701486)。
Magnetocardiography(MCG)measurement is important for investigating the cardiac biological activities.Traditionally,the extremely weak MCG signal was detected by using superconducting quantum interference devices(SQUID...
Objective: The purpose of this work is to examine the usefulness of the topological approach for analysis of current density maps during ST-T interval in detection of coronary artery disease (CAD) in patients with pro...
supported by the National Natural Science Foundation of China(60771030);the National HighTechnology Research and Development Program of China(2008AA02Z308);the Shanghai Science and Technology Development Foundation(08JC1421800);Shanghai Leading Academic Discipline Project(B004);the Open Project of State Key Laboratory of Function Materials for Information(Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences)
Cardiac current source reconstruction is investigated by a fast greedy sparse(FGS) method applied to simulated and real magnetocardiography(MCG) data measured using 61-channel superconducting quantum interference devi...
Project supported by"One Hundred Persons Project"of the Chinese Academy of Sciences and the Strategic Priority Research Program(B)of the Chinese Academy of Sciences(Grant No.XDB04020200)
We constructed a 36-channel magnetocardiography(MCG) system based on low-Tc direct current(DC) superconducting quantum interference device(SQUID) magnetometers operated inside a magnetically shielded room(MSR)...
supported by the "Strategic Priority Research Program(B)"of the Chinese Academy of Sciences(Grant No.XDB04020200);the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant No.KGCX2-EW-105)
SQUID gradiometer techniques are widely used in noise cancellation for biomagnetic measurements.An appropriate gradiometer baseline is very important for the biomagnetic detection with high performance.By placing seve...
Project supported by the Main Direction Program of Knowledge Innovation of the Chinese Academy of Sciences(Grant No.KGCX2-EW-105);the "100 Talents Project" of the Chinese Academy of Sciences and Strategic Priority Research Program(B)of the Chinese Academy of Sciences(Grant No.XDB04020200)
A dual-washer superconducting quantum interference device (SQUID) with a loop inductance of 350 pH and two on- washer integrated input coils is designed according to conventional niobium technology. In order to obta...
Objective: Non-invasive methods of evaluation of electrical activity of the heart are still the most important functional diagnostics methods in coronary artery disease (CAD) detection. It has been shown that magnetoc...