电感耦合等离子体质谱法测定保健食品中的硒  被引量:9

Determination of Selenium in Health Food by Inductively Coupled Plasma Mass Spectrometry

在线阅读下载全文

作  者:高飞[1] 张剑峰[1] 历荣[2] 刘秀梅[1] 金宏伟[1] 

机构地区:[1]黑龙江省疾病预防控制中心,黑龙江哈尔滨150030 [2]黑龙江大学

出  处:《中国卫生工程学》2009年第3期172-173,共2页Chinese Journal of Public Health Engineering

摘  要:目的建立电感耦合等离子体质谱(ICP—MS)测定富硒保健食品中硒元素的方法。方法以市售富硒保健食品为研究对象,样品经高压微波消解处理后,应用ICP—MS测定其中硒元素含量。结果本研究方法测定的硒元素的标准曲线线性相关系数为0.9999;加标回收率范围在99.40%-100.15%;检出限为0.078μg/L;相对标准偏差范围在0.91%~2.65%。结论该方法具有快速、简便、灵敏、准确的优点,适用于保健食品中硒元素的测定。Objective To establish an inductively coupled plasma mass spectrometry ( ICP - MS) method for determination of selenium (Se) in Se - enriched health food. Methods ICP - MS was adopted to determine Se element in Se - enriched healthy food sold in market after microwave digestion. Results The correlative coefficients of the calibration curve was 0. 999 9 ,recoveries of standard addition were 99.40% - 100. 15% with the RSD of 0. 91% - 2.65%. The detection limit was 0. 078 μg/l. Conclusion The method has the advantages of speediness, simplicity, accuracy, sensitivity,it is suitable for determination of Se in health food.

关 键 词:电感耦合等离子体值谱法  保健食品 

分 类 号:R151[医药卫生—营养与食品卫生学] O53[医药卫生—公共卫生与预防医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象